{"title":"All Hi-Velocity Parts \u0026 Accessories","description":null,"products":[{"product_id":"hi-velocity-wcm-50-chilled-water-module","title":"Hi-Velocity WCM-50 Chilled Water Module Chilled Water Coil","description":"\u003cp\u003eThe \u003cstrong\u003eWCM-50 Chilled Water Module\u003c\/strong\u003e is a high-capacity hydronic water coil installed on the return-air side of the air handler as a retrofit add-on cooling module. Chilled-water primary use, but also usable for heating with water temperatures up to 130°F (54°C). Rated for 18–24 MBH cooling at 42°F EWT.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm)\u003c\/li\u003e\n\u003cli\u003eDrain pan with two 3\/4\" drain connections (primary + secondary)\u003c\/li\u003e\n\u003cli\u003eTwo L-mounting brackets for retrofit attachment\u003c\/li\u003e\n\u003cli\u003eApproved for potable water systems\u003c\/li\u003e\n\u003cli\u003eReverse-usable for heating up to 130°F EWT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity WCM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e18–24 MBH (5.3–7.0 kW) @ 42°F EWT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eGPM flow rating\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e5 GPM (0.32 L\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSupply line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eReturn line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-B\/HE-50\/51, HV-50\/51\/52, CU-51, LV-Z\/LV-B-750\/751, LV-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e26 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e20\"x11\"x19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eRetrofit chilled-water cooling for an existing Hi-Velocity SDHV air handler. Also serves as the cooling coil for water-source heat pumps and reverse-cycle chiller installations. Use the WBM base module in new-build installations.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-wcm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eWCM Chilled Water Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819703202073,"sku":"10010201050","price":995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-wcm-hero-1.png?v=1784417932"},{"product_id":"hi-velocity-wcm-70-1050-chilled-water-module","title":"Hi-Velocity WCM-70\/1050 Chilled Water Module Chilled Water Coil","description":"\u003cp\u003eThe \u003cstrong\u003eWCM-70\/1050 Chilled Water Module\u003c\/strong\u003e is a high-capacity hydronic water coil installed on the return-air side of the air handler as a retrofit add-on cooling module. Chilled-water primary use, but also usable for heating with water temperatures up to 130°F (54°C). Rated for 30–36 MBH cooling at 42°F EWT.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm)\u003c\/li\u003e\n\u003cli\u003eDrain pan with two 3\/4\" drain connections (primary + secondary)\u003c\/li\u003e\n\u003cli\u003eTwo L-mounting brackets for retrofit attachment\u003c\/li\u003e\n\u003cli\u003eApproved for potable water systems\u003c\/li\u003e\n\u003cli\u003eReverse-usable for heating up to 130°F EWT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity WCM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e30–36 MBH (8.8–10.6 kW) @ 42°F EWT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eGPM flow rating\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e7 GPM (0.44 L\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSupply line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eReturn line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-B\/HE\/HV-70\/71, LV-Z\/LV-B-1050\/1051, LV-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e33 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e24\"x11\"x19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eRetrofit chilled-water cooling for an existing Hi-Velocity SDHV air handler. Also serves as the cooling coil for water-source heat pumps and reverse-cycle chiller installations. Use the WBM base module in new-build installations.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-wcm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eWCM Chilled Water Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819703234841,"sku":"10010201070","price":1091.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-wcm-hero-1.png?v=1784417932"},{"product_id":"hi-velocity-hwc-30-hot-water-coil","title":"Hi-Velocity HWC-30 Hot Water Coil","description":"\u003cp\u003eThe \u003cstrong\u003eHWC-30 Hot Water Coil\u003c\/strong\u003e is a high-capacity hydronic heating coil for Hi-Velocity SDHV air handlers. Pre-installed in H-series heating units and field-installable in BU blower units. Rated for 26,900 BTUH at 180°F entering water temperature.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e6 internal rows of 3\/8\" copper tubing\u003c\/li\u003e\n\u003cli\u003eFactory-tested at 500 psi for leaks\u003c\/li\u003e\n\u003cli\u003eLow water-side pressure drop — reduces pump head\u003c\/li\u003e\n\u003cli\u003eCompatible with dual-purpose hot water tanks (gas or oil), boilers (gas \/ oil \/ electric \/ wood-fired) and solar heating systems\u003c\/li\u003e\n\u003cli\u003eApproved for potable water systems\u003c\/li\u003e\n\u003cli\u003eInstalls vertically in air handler cabinet — slides in via front blower panels\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity HWC Series (Hot-Water Coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax BTUH heating @ 180°F EWT\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e26,900 BTUH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eGPM flow rating\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSupply \/ return connections\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/8\" copper (6-row)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eJH-15\/30, CU-31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFactory pressure test\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e500 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e20\"x4\"x17\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eStandard hydronic heating coil for the Hi-Velocity SDHV line. Pairs with residential or commercial boilers, condensing wall-hung boilers, dual-purpose hot-water tanks and solar-heating loops. For chilled-water cooling loops or geothermal \/ reverse-cycle chiller sources, use the WCM or WBM module (which includes a drain pan for cooling condensate).\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-hwc-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHot Water Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819704512793,"sku":"10050500030","price":433.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-hwc-6-row-vertical-1.png?v=1784417888"},{"product_id":"hi-velocity-rcm-50-r410a-tx-cooling-module","title":"Hi-Velocity RCM-50-R410A TX Cooling Module Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRCM-50-R410A TX Cooling Module\u003c\/strong\u003e is the R-410A configuration of the RCM-50 Refrigerant Cooling Module — a heat-pump-ready TX cooling coil designed as an add-on to an existing Hi-Velocity air handler. Mounts on the return-air side using two L-mounting brackets, with its own drain pan and dual 3\/4\" drain connections. Rated for 1.5–2.0 tons of cooling (18–24 MBH).\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm)\u003c\/li\u003e\n\u003cli\u003eDrain pan with two 3\/4\" drain connections (primary + secondary)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-410A TX expansion valve with built-in check valve — heat-pump-ready\u003c\/li\u003e\n\u003cli\u003eTwo L-mounting brackets for retrofit air-handler attachment\u003c\/li\u003e\n\u003cli\u003eFreeze stat, access port(s) and carry-over screen included\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RCM Series (Refrigerant Cooling Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal cooling tonnage\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e1.5–2.0 tons (5.3–7.0 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTX cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e18–24 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLiquid line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSuction line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-B\/HE\/HV-50\/51, CU-51, LV-Z\/LV-B-750\/751, LV-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eIncludes\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eTXV, freeze stat, access ports, carry-over screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e27 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e18\"x11\"x19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eThe RCM series is the retrofit cooling upgrade for an already-installed Hi-Velocity air handler — L-mount brackets allow attachment to the return-air side without dismantling the base unit. For new-build installations where cooling is specified up-front, the RBM base module is typically the cleaner mechanical solution.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRCM Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819704545561,"sku":"10090200050","price":1174.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-hero-1.png?v=1784417899"},{"product_id":"hi-velocity-rcm-70-r410a-tx-cooling-module","title":"Hi-Velocity RCM-70-R410A TX Cooling Module Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRCM-70-R410A TX Cooling Module\u003c\/strong\u003e is the R-410A configuration of the RCM-70 Refrigerant Cooling Module — a heat-pump-ready TX cooling coil designed as an add-on to an existing Hi-Velocity air handler. Mounts on the return-air side using two L-mounting brackets, with its own drain pan and dual 3\/4\" drain connections. Rated for 2.5–3.0 tons of cooling (30–36 MBH).\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm)\u003c\/li\u003e\n\u003cli\u003eDrain pan with two 3\/4\" drain connections (primary + secondary)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-410A TX expansion valve with built-in check valve — heat-pump-ready\u003c\/li\u003e\n\u003cli\u003eTwo L-mounting brackets for retrofit air-handler attachment\u003c\/li\u003e\n\u003cli\u003eFreeze stat, access port(s) and carry-over screen included\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RCM Series (Refrigerant Cooling Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal cooling tonnage\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e2.5–3.0 tons (8.8–10.6 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTX cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e30–36 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLiquid line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSuction line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-B\/HE\/HV-70\/71, LV-Z\/LV-B-1050\/1051, LV-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eIncludes\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eTXV, freeze stat, access ports, carry-over screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e34 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e23\"x11\"x19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eThe RCM series is the retrofit cooling upgrade for an already-installed Hi-Velocity air handler — L-mount brackets allow attachment to the return-air side without dismantling the base unit. For new-build installations where cooling is specified up-front, the RBM base module is typically the cleaner mechanical solution.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRCM Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819704578329,"sku":"10090200070","price":1439.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-hero-1.png?v=1784417899"},{"product_id":"hi-velocity-rcm-50-a2l-r-454b-r-32-tx-refrigerant-module-w-rds-kit","title":"Hi-Velocity RCM-50-A2L (R-454B\/R-32) TX Refrigerant Module w\/ RDS Kit Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRCM-50-A2L (R-454B\/R-32) TX Refrigerant Module w\/ RDS Kit\u003c\/strong\u003e is the R-454B \/ R-32 (A2L) configuration of the RCM-50 Refrigerant Cooling Module — a heat-pump-ready TX cooling coil designed as an add-on to an existing Hi-Velocity air handler. Mounts on the return-air side using two L-mounting brackets, with its own drain pan and dual 3\/4\" drain connections. Rated for 1.5–2.0 tons of cooling (18–24 MBH). Ships with the RDS Kit (mitigation board + refrigerant sensor) required for A2L installations.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm)\u003c\/li\u003e\n\u003cli\u003eDrain pan with two 3\/4\" drain connections (primary + secondary)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-454B \/ R-32 (A2L) TX expansion valve with built-in check valve — heat-pump-ready\u003c\/li\u003e\n\u003cli\u003eTwo L-mounting brackets for retrofit air-handler attachment\u003c\/li\u003e\n\u003cli\u003eFreeze stat, access port(s) and carry-over screen included\u003c\/li\u003e\n\u003cli\u003eRDS Kit — mitigation board and pre-installed A2L refrigerant sensor\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RCM Series (Refrigerant Cooling Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-454B \/ R-32 (A2L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal cooling tonnage\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e1.5–2.0 tons (5.3–7.0 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTX cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e18–24 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLiquid line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSuction line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-B\/HE\/HV-50\/51, CU-51, LV-Z\/LV-B-750\/751, LV-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eIncludes\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRDS Kit (mitigation board + refrigerant sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e27 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e18\"x11\"x19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eThe RCM series is the retrofit cooling upgrade for an already-installed Hi-Velocity air handler — L-mount brackets allow attachment to the return-air side without dismantling the base unit. For new-build installations where cooling is specified up-front, the RBM base module is typically the cleaner mechanical solution.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRCM Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819704611097,"sku":"10090204050","price":1928.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-hero-1.png?v=1784417899"},{"product_id":"hi-velocity-rcm-70-a2l-r-454b-r-32-tx-refrigerant-module-w-rds-kit","title":"Hi-Velocity RCM-70-A2L (R-454B\/R-32) TX Refrigerant Module w\/ RDS Kit Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRCM-70-A2L (R-454B\/R-32) TX Refrigerant Module w\/ RDS Kit\u003c\/strong\u003e is the R-454B \/ R-32 (A2L) configuration of the RCM-70 Refrigerant Cooling Module — a heat-pump-ready TX cooling coil designed as an add-on to an existing Hi-Velocity air handler. Mounts on the return-air side using two L-mounting brackets, with its own drain pan and dual 3\/4\" drain connections. Rated for 2.5–3.0 tons of cooling (30–36 MBH). Ships with the RDS Kit (mitigation board + refrigerant sensor) required for A2L installations.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm)\u003c\/li\u003e\n\u003cli\u003eDrain pan with two 3\/4\" drain connections (primary + secondary)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-454B \/ R-32 (A2L) TX expansion valve with built-in check valve — heat-pump-ready\u003c\/li\u003e\n\u003cli\u003eTwo L-mounting brackets for retrofit air-handler attachment\u003c\/li\u003e\n\u003cli\u003eFreeze stat, access port(s) and carry-over screen included\u003c\/li\u003e\n\u003cli\u003eRDS Kit — mitigation board and pre-installed A2L refrigerant sensor\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RCM Series (Refrigerant Cooling Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-454B \/ R-32 (A2L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal cooling tonnage\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e2.5–3.0 tons (8.8–10.6 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTX cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e30–36 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLiquid line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSuction line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-B\/HE\/HV-70\/71, LV-Z\/LV-B-1050\/1051, LV-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eIncludes\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRDS Kit (mitigation board + refrigerant sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e34 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e23\"x11\"x19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eThe RCM series is the retrofit cooling upgrade for an already-installed Hi-Velocity air handler — L-mount brackets allow attachment to the return-air side without dismantling the base unit. For new-build installations where cooling is specified up-front, the RBM base module is typically the cleaner mechanical solution.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRCM Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819704643865,"sku":"10090204070","price":2259.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-hero-1.png?v=1784417899"},{"product_id":"hi-velocity-wm-1750-chilled-water-module","title":"Hi-Velocity WM-1750 Chilled Water Module Chilled Water Coil","description":"\u003cp\u003eThe \u003cstrong\u003eWM-1750 Chilled Water Module\u003c\/strong\u003e is a high-capacity hydronic water coil installed on the return-air side of the air handler as a retrofit add-on cooling module. Chilled-water primary use, but also usable for heating with water temperatures up to 130°F (54°C). Rated for 42–70 MBH cooling at 42°F EWT.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm)\u003c\/li\u003e\n\u003cli\u003eDrain pan with two 3\/4\" drain connections (primary + secondary)\u003c\/li\u003e\n\u003cli\u003eTwo L-mounting brackets for retrofit attachment\u003c\/li\u003e\n\u003cli\u003eApproved for potable water systems\u003c\/li\u003e\n\u003cli\u003eReverse-usable for heating up to 130°F EWT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity WM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e42–70 MBH (12.3–20.5 kW) @ 42°F EWT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eGPM flow rating\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10 GPM (0.63 L\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSupply line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eReturn line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-P-240\/241, LV-Z\/LV-B-1750\/1751\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e55 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e30\"x9\"x23\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eRetrofit chilled-water cooling for an existing Hi-Velocity SDHV air handler. Also serves as the cooling coil for water-source heat pumps and reverse-cycle chiller installations. Use the WBM base module in new-build installations.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819704906009,"sku":"20090101750","price":2258.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-wcm-hero-1.png?v=1784417932"},{"product_id":"hi-velocity-hwc-50-hot-water-coil","title":"Hi-Velocity HWC-50 Hot Water Coil","description":"\u003cp\u003eThe \u003cstrong\u003eHWC-50 Hot Water Coil\u003c\/strong\u003e is a high-capacity hydronic heating coil for Hi-Velocity SDHV air handlers. Pre-installed in H-series heating units and field-installable in BU blower units. Rated for 54,500 BTUH at 180°F entering water temperature.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e6 internal rows of 3\/8\" copper tubing\u003c\/li\u003e\n\u003cli\u003eFactory-tested at 500 psi for leaks\u003c\/li\u003e\n\u003cli\u003eLow water-side pressure drop — reduces pump head\u003c\/li\u003e\n\u003cli\u003eCompatible with dual-purpose hot water tanks (gas or oil), boilers (gas \/ oil \/ electric \/ wood-fired) and solar heating systems\u003c\/li\u003e\n\u003cli\u003eApproved for potable water systems\u003c\/li\u003e\n\u003cli\u003eInstalls vertically in air handler cabinet — slides in via front blower panels\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity HWC Series (Hot-Water Coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax BTUH heating @ 180°F EWT\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e54,500 BTUH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eGPM flow rating\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e5 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSupply \/ return connections\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/8\" copper (6-row)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-B\/HE-50\/51, HV-50\/51, CU-51, LV-Z\/LV-B-750\/751, LV-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFactory pressure test\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e500 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e17 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e16\"x6\"x16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eStandard hydronic heating coil for the Hi-Velocity SDHV line. Pairs with residential or commercial boilers, condensing wall-hung boilers, dual-purpose hot-water tanks and solar-heating loops. For chilled-water cooling loops or geothermal \/ reverse-cycle chiller sources, use the WCM or WBM module (which includes a drain pan for cooling condensate).\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-hwc-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHot Water Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819704938777,"sku":"20100100050","price":956.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-hwc-6-row-vertical-1.png?v=1784417888"},{"product_id":"hi-velocity-hwc-52-hot-water-coil","title":"Hi-Velocity HWC-52 Hot Water Coil","description":"\u003cp\u003eThe \u003cstrong\u003eHWC-52 Hot Water Coil\u003c\/strong\u003e is a high-capacity hydronic heating coil for Hi-Velocity SDHV air handlers. Pre-installed in H-series heating units and field-installable in BU blower units. Rated for 54,500 BTUH at 180°F entering water temperature.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e6 internal rows of 3\/8\" copper tubing\u003c\/li\u003e\n\u003cli\u003eFactory-tested at 500 psi for leaks\u003c\/li\u003e\n\u003cli\u003eLow water-side pressure drop — reduces pump head\u003c\/li\u003e\n\u003cli\u003eCompatible with dual-purpose hot water tanks (gas or oil), boilers (gas \/ oil \/ electric \/ wood-fired) and solar heating systems\u003c\/li\u003e\n\u003cli\u003eApproved for potable water systems\u003c\/li\u003e\n\u003cli\u003eInstalls vertically in air handler cabinet — slides in via front blower panels\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity HWC Series (Hot-Water Coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax BTUH heating @ 180°F EWT\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e54,500 BTUH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eGPM flow rating\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e5 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSupply \/ return connections\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/8\" copper (6-row)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE\/HV-52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFactory pressure test\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e500 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e17 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e22\"x6\"x16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eStandard hydronic heating coil for the Hi-Velocity SDHV line. Pairs with residential or commercial boilers, condensing wall-hung boilers, dual-purpose hot-water tanks and solar-heating loops. For chilled-water cooling loops or geothermal \/ reverse-cycle chiller sources, use the WCM or WBM module (which includes a drain pan for cooling condensate).\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-hwc-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHot Water Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819704971545,"sku":"20100100052","price":1092.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-hwc-6-row-vertical-1.png?v=1784417888"},{"product_id":"hi-velocity-hwc-70-1050-hot-water-coil","title":"Hi-Velocity HWC-70\/1050 Hot Water Coil","description":"\u003cp\u003eThe \u003cstrong\u003eHWC-70\/1050 Hot Water Coil\u003c\/strong\u003e is a high-capacity hydronic heating coil for Hi-Velocity SDHV air handlers. Pre-installed in H-series heating units and field-installable in BU blower units. Rated for 81,800 BTUH at 180°F entering water temperature.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e6 internal rows of 3\/8\" copper tubing\u003c\/li\u003e\n\u003cli\u003eFactory-tested at 500 psi for leaks\u003c\/li\u003e\n\u003cli\u003eLow water-side pressure drop — reduces pump head\u003c\/li\u003e\n\u003cli\u003eCompatible with dual-purpose hot water tanks (gas or oil), boilers (gas \/ oil \/ electric \/ wood-fired) and solar heating systems\u003c\/li\u003e\n\u003cli\u003eApproved for potable water systems\u003c\/li\u003e\n\u003cli\u003eInstalls vertically in air handler cabinet — slides in via front blower panels\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity HWC Series (Hot-Water Coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax BTUH heating @ 180°F EWT\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e81,800 BTUH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eGPM flow rating\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e7 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSupply \/ return connections\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/8\" copper (6-row)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-B\/HE-70\/71, HV-70\/71, LV-Z\/LV-B-1050\/1051, LV-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFactory pressure test\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e500 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e22 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e22\"x6\"x16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eStandard hydronic heating coil for the Hi-Velocity SDHV line. Pairs with residential or commercial boilers, condensing wall-hung boilers, dual-purpose hot-water tanks and solar-heating loops. For chilled-water cooling loops or geothermal \/ reverse-cycle chiller sources, use the WCM or WBM module (which includes a drain pan for cooling condensate).\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-hwc-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHot Water Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705004313,"sku":"20100100070","price":966.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-hwc-6-row-vertical-1.png?v=1784417888"},{"product_id":"hi-velocity-hwc-100-hot-water-coil","title":"Hi-Velocity HWC-100 Hot Water Coil","description":"\u003cp\u003eThe \u003cstrong\u003eHWC-100 Hot Water Coil\u003c\/strong\u003e is a high-capacity hydronic heating coil for Hi-Velocity SDHV air handlers. Pre-installed in H-series heating units and field-installable in BU blower units. Rated for 122,900 BTUH at 180°F entering water temperature.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e6 internal rows of 3\/8\" copper tubing\u003c\/li\u003e\n\u003cli\u003eFactory-tested at 500 psi for leaks\u003c\/li\u003e\n\u003cli\u003eLow water-side pressure drop — reduces pump head\u003c\/li\u003e\n\u003cli\u003eCompatible with dual-purpose hot water tanks (gas or oil), boilers (gas \/ oil \/ electric \/ wood-fired) and solar heating systems\u003c\/li\u003e\n\u003cli\u003eApproved for potable water systems\u003c\/li\u003e\n\u003cli\u003eInstalls vertically in air handler cabinet — slides in via front blower panels\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity HWC Series (Hot-Water Coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax BTUH heating @ 180°F EWT\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e122,900 BTUH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eGPM flow rating\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSupply \/ return connections\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/8\" copper (6-row)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-P-100\/101, HE-B-100\/101, HE\/HV-100\/101, LV-120\/140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFactory pressure test\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e500 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e29 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e28\"x6\"x16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eStandard hydronic heating coil for the Hi-Velocity SDHV line. Pairs with residential or commercial boilers, condensing wall-hung boilers, dual-purpose hot-water tanks and solar-heating loops. For chilled-water cooling loops or geothermal \/ reverse-cycle chiller sources, use the WCM or WBM module (which includes a drain pan for cooling condensate).\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-hwc-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHot Water Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705037081,"sku":"20100100100","price":1348.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-hwc-6-row-vertical-1.png?v=1784417888"},{"product_id":"hi-velocity-hwc-1750-hot-water-coil","title":"Hi-Velocity HWC-1750 Hot Water Coil","description":"\u003cp\u003eThe \u003cstrong\u003eHWC-1750 Hot Water Coil\u003c\/strong\u003e is a high-capacity hydronic heating coil for Hi-Velocity SDHV air handlers. Pre-installed in H-series heating units and field-installable in BU blower units. Rated for 137,000 BTUH at 180°F entering water temperature.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e6 internal rows of 3\/8\" copper tubing\u003c\/li\u003e\n\u003cli\u003eFactory-tested at 500 psi for leaks\u003c\/li\u003e\n\u003cli\u003eLow water-side pressure drop — reduces pump head\u003c\/li\u003e\n\u003cli\u003eCompatible with dual-purpose hot water tanks (gas or oil), boilers (gas \/ oil \/ electric \/ wood-fired) and solar heating systems\u003c\/li\u003e\n\u003cli\u003eApproved for potable water systems\u003c\/li\u003e\n\u003cli\u003eInstalls vertically in air handler cabinet — slides in via front blower panels\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity HWC Series (Hot-Water Coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax BTUH heating @ 180°F EWT\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e137,000 BTUH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eGPM flow rating\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSupply \/ return connections\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/8\" copper (6-row)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-P-240\/241, HV-140, LV-Z\/LV-B-1750\/1751\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFactory pressure test\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e500 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e45 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e28\"x6\"x22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eStandard hydronic heating coil for the Hi-Velocity SDHV line. Pairs with residential or commercial boilers, condensing wall-hung boilers, dual-purpose hot-water tanks and solar-heating loops. For chilled-water cooling loops or geothermal \/ reverse-cycle chiller sources, use the WCM or WBM module (which includes a drain pan for cooling condensate).\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-hwc-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHot Water Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705069849,"sku":"20100101750","price":1647.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-hwc-6-row-vertical-1.png?v=1784417888"},{"product_id":"hi-velocity-wcm-100-chilled-water-module","title":"Hi-Velocity WCM-100 Chilled Water Module Chilled Water Coil","description":"\u003cp\u003eThe \u003cstrong\u003eWCM-100 Chilled Water Module\u003c\/strong\u003e is a high-capacity hydronic water coil installed on the return-air side of the air handler as a retrofit add-on cooling module. Chilled-water primary use, but also usable for heating with water temperatures up to 130°F (54°C). Rated for 42–60 MBH cooling at 42°F EWT.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm)\u003c\/li\u003e\n\u003cli\u003eDrain pan with two 3\/4\" drain connections (primary + secondary)\u003c\/li\u003e\n\u003cli\u003eTwo L-mounting brackets for retrofit attachment\u003c\/li\u003e\n\u003cli\u003eApproved for potable water systems\u003c\/li\u003e\n\u003cli\u003eReverse-usable for heating up to 130°F EWT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity WCM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e42–60 MBH (12.3–17.6 kW) @ 42°F EWT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eGPM flow rating\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10 GPM (0.63 L\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSupply line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eReturn line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-B\/HE-100\/101, HV-100\/101, LV-Z\/LV-B-1050\/1051, LV-120\/140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e44 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e30\"x11\"x20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eRetrofit chilled-water cooling for an existing Hi-Velocity SDHV air handler. Also serves as the cooling coil for water-source heat pumps and reverse-cycle chiller installations. Use the WBM base module in new-build installations.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-wcm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eWCM Chilled Water Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705102617,"sku":"40090100100","price":1455.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-wcm-hero-1.png?v=1784417932"},{"product_id":"hi-velocity-rcm-30-r410a-dx-cooling-module","title":"Hi-Velocity RCM-30-R410A DX Cooling Module Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRCM-30-R410A DX Cooling Module\u003c\/strong\u003e is the R-410A configuration of the RCM-30 Refrigerant Cooling Module — a heat-pump-ready DX cooling coil designed as an add-on to an existing Hi-Velocity air handler. Mounts on the return-air side using two L-mounting brackets, with its own drain pan and dual 3\/4\" drain connections. Rated for 1.0 tons of cooling (6–12 MBH).\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm)\u003c\/li\u003e\n\u003cli\u003eDrain pan with two 3\/4\" drain connections (primary + secondary)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-410A DX expansion valve with built-in check valve — heat-pump-ready\u003c\/li\u003e\n\u003cli\u003eTwo L-mounting brackets for retrofit air-handler attachment\u003c\/li\u003e\n\u003cli\u003eFreeze stat, access port(s) and carry-over screen included\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RCM Series (Refrigerant Cooling Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal cooling tonnage\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e1.0 tons (3.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDX cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e6–12 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLiquid line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSuction line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eCU-31, JH-15\/30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eIncludes\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eTXV, freeze stat, access ports, carry-over screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e17 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e17\"x14\"x21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eThe RCM series is the retrofit cooling upgrade for an already-installed Hi-Velocity air handler — L-mount brackets allow attachment to the return-air side without dismantling the base unit. For new-build installations where cooling is specified up-front, the RBM base module is typically the cleaner mechanical solution.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRCM Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705135385,"sku":"40090200030","price":884.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-hero-1.png?v=1784417899"},{"product_id":"hi-velocity-rcm-100-r410a-tx-cooling-module","title":"Hi-Velocity RCM-100-R410A TX Cooling Module Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRCM-100-R410A TX Cooling Module\u003c\/strong\u003e is the R-410A configuration of the RCM-100 Refrigerant Cooling Module — a heat-pump-ready TX cooling coil designed as an add-on to an existing Hi-Velocity air handler. Mounts on the return-air side using two L-mounting brackets, with its own drain pan and dual 3\/4\" drain connections. Rated for 3.5–5.0 tons of cooling (42–60 MBH).\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm)\u003c\/li\u003e\n\u003cli\u003eDrain pan with two 3\/4\" drain connections (primary + secondary)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-410A TX expansion valve with built-in check valve — heat-pump-ready\u003c\/li\u003e\n\u003cli\u003eTwo L-mounting brackets for retrofit air-handler attachment\u003c\/li\u003e\n\u003cli\u003eFreeze stat, access port(s) and carry-over screen included\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RCM Series (Refrigerant Cooling Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal cooling tonnage\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3.5–5.0 tons (12.3–17.6 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTX cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e42–60 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLiquid line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSuction line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-P\/HE-B\/HE\/HV-100\/101, HE-P-240\/241 (×2 coils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eIncludes\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eTXV, freeze stat, access ports, carry-over screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e45 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e30\"x11\"x20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eThe RCM series is the retrofit cooling upgrade for an already-installed Hi-Velocity air handler — L-mount brackets allow attachment to the return-air side without dismantling the base unit. For new-build installations where cooling is specified up-front, the RBM base module is typically the cleaner mechanical solution.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRCM Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705168153,"sku":"40090200100","price":1738.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-hero-1.png?v=1784417899"},{"product_id":"hi-velocity-rcm-30-a2l-r-454b-r-32-dx-refrigerant-module-w-rds-kit","title":"Hi-Velocity RCM-30-A2L (R-454B\/R-32) DX Refrigerant Module w\/ RDS Kit Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRCM-30-A2L (R-454B\/R-32) DX Refrigerant Module w\/ RDS Kit\u003c\/strong\u003e is the R-454B \/ R-32 (A2L) configuration of the RCM-30 Refrigerant Cooling Module — a heat-pump-ready DX cooling coil designed as an add-on to an existing Hi-Velocity air handler. Mounts on the return-air side using two L-mounting brackets, with its own drain pan and dual 3\/4\" drain connections. Rated for 1.0 tons of cooling (6–12 MBH). Ships with the RDS Kit (mitigation board + refrigerant sensor) required for A2L installations.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm)\u003c\/li\u003e\n\u003cli\u003eDrain pan with two 3\/4\" drain connections (primary + secondary)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-454B \/ R-32 (A2L) DX expansion valve with built-in check valve — heat-pump-ready\u003c\/li\u003e\n\u003cli\u003eTwo L-mounting brackets for retrofit air-handler attachment\u003c\/li\u003e\n\u003cli\u003eFreeze stat, access port(s) and carry-over screen included\u003c\/li\u003e\n\u003cli\u003eRDS Kit — mitigation board and pre-installed A2L refrigerant sensor\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RCM Series (Refrigerant Cooling Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-454B \/ R-32 (A2L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal cooling tonnage\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e1.0 tons (3.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDX cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e6–12 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLiquid line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSuction line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eCU-31, JH-15\/30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eIncludes\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRDS Kit (mitigation board + refrigerant sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e17 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e17\"x14\"x21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eThe RCM series is the retrofit cooling upgrade for an already-installed Hi-Velocity air handler — L-mount brackets allow attachment to the return-air side without dismantling the base unit. For new-build installations where cooling is specified up-front, the RBM base module is typically the cleaner mechanical solution.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRCM Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705200921,"sku":"40090204030","price":1432.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-hero-1.png?v=1784417899"},{"product_id":"hi-velocity-rcm-100-a2l-r-454b-r-32-tx-refrigerant-module-w-rds-kit","title":"Hi-Velocity RCM-100-A2L (R-454B\/R-32) TX Refrigerant Module w\/ RDS Kit Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRCM-100-A2L (R-454B\/R-32) TX Refrigerant Module w\/ RDS Kit\u003c\/strong\u003e is the R-454B \/ R-32 (A2L) configuration of the RCM-100 Refrigerant Cooling Module — a heat-pump-ready TX cooling coil designed as an add-on to an existing Hi-Velocity air handler. Mounts on the return-air side using two L-mounting brackets, with its own drain pan and dual 3\/4\" drain connections. Rated for 3.5–5.0 tons of cooling (42–60 MBH). Ships with the RDS Kit (mitigation board + refrigerant sensor) required for A2L installations.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm)\u003c\/li\u003e\n\u003cli\u003eDrain pan with two 3\/4\" drain connections (primary + secondary)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-454B \/ R-32 (A2L) TX expansion valve with built-in check valve — heat-pump-ready\u003c\/li\u003e\n\u003cli\u003eTwo L-mounting brackets for retrofit air-handler attachment\u003c\/li\u003e\n\u003cli\u003eFreeze stat, access port(s) and carry-over screen included\u003c\/li\u003e\n\u003cli\u003eRDS Kit — mitigation board and pre-installed A2L refrigerant sensor\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RCM Series (Refrigerant Cooling Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-454B \/ R-32 (A2L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal cooling tonnage\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3.5–5.0 tons (12.3–17.6 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTX cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e42–60 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLiquid line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSuction line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-P\/HE-B\/HE\/HV-100\/101, HE-P-240\/241 (×2 coils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eIncludes\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRDS Kit (mitigation board + refrigerant sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e45 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e30\"x11\"x20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eThe RCM series is the retrofit cooling upgrade for an already-installed Hi-Velocity air handler — L-mount brackets allow attachment to the return-air side without dismantling the base unit. For new-build installations where cooling is specified up-front, the RBM base module is typically the cleaner mechanical solution.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRCM Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705233689,"sku":"40090204100","price":2558.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-hero-1.png?v=1784417899"},{"product_id":"hi-velocity-wbm-50-chilled-water-base-module","title":"Hi-Velocity WBM-50 Chilled Water Base Module Chilled Water Coil","description":"\u003cp\u003eThe \u003cstrong\u003eWBM-50 Chilled Water Base Module\u003c\/strong\u003e is a chilled-water base cooling coil designed to install directly under the air handler — the same T-mount base configuration as the RBM refrigerant module, but with hydronic connections for chilled water or water-source heat pump systems. Rated for 18–24 MBH cooling at 42°F EWT.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm)\u003c\/li\u003e\n\u003cli\u003eDrain pan with two 3\/4\" M CPVC drain connections (primary + secondary, both P-trap and vented)\u003c\/li\u003e\n\u003cli\u003eTwo T-mounting brackets for base attachment\u003c\/li\u003e\n\u003cli\u003eCompatible with glycol solutions (see manufacturer reduction charts for capacity derating)\u003c\/li\u003e\n\u003cli\u003eApproved for potable water systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity WBM Series (Chilled-Water Base Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e18–24 MBH (5.3–7.0 kW) @ 42°F EWT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eGPM flow rating\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e5 GPM (0.32 L\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSupply line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eReturn line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC (primary + secondary)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-B\/HE\/HV-50\/51\/52, CU-51, LV-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e35 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e37\"x19\"x23\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eThe WBM series pairs with chilled-water systems, geothermal loops, water-to-water heat pumps and reverse-cycle chillers — anywhere hydronic cooling is the design of record. For retrofit chilled-water cooling on an already-installed air handler, the WCM add-on module is the return-air-side equivalent.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-wbm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eWBM Chilled Water Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705266457,"sku":"40090400050","price":1111.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-wbm-hero-1.png?v=1784417932"},{"product_id":"hi-velocity-wbm-70-1050-chilled-water-base-module","title":"Hi-Velocity WBM-70\/1050 Chilled Water Base Module Chilled Water Coil","description":"\u003cp\u003eThe \u003cstrong\u003eWBM-70\/1050 Chilled Water Base Module\u003c\/strong\u003e is a chilled-water base cooling coil designed to install directly under the air handler — the same T-mount base configuration as the RBM refrigerant module, but with hydronic connections for chilled water or water-source heat pump systems. Rated for 30–36 MBH cooling at 42°F EWT.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm)\u003c\/li\u003e\n\u003cli\u003eDrain pan with two 3\/4\" M CPVC drain connections (primary + secondary, both P-trap and vented)\u003c\/li\u003e\n\u003cli\u003eTwo T-mounting brackets for base attachment\u003c\/li\u003e\n\u003cli\u003eCompatible with glycol solutions (see manufacturer reduction charts for capacity derating)\u003c\/li\u003e\n\u003cli\u003eApproved for potable water systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity WBM Series (Chilled-Water Base Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e30–36 MBH (8.8–10.6 kW) @ 42°F EWT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eGPM flow rating\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e7 GPM (0.44 L\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSupply line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eReturn line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC (primary + secondary)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-B\/HE\/HV-70\/71, LV-70, LV-Z\/LV-E-1050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e45 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e37\"x19\"x23\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eThe WBM series pairs with chilled-water systems, geothermal loops, water-to-water heat pumps and reverse-cycle chillers — anywhere hydronic cooling is the design of record. For retrofit chilled-water cooling on an already-installed air handler, the WCM add-on module is the return-air-side equivalent.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-wbm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eWBM Chilled Water Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705299225,"sku":"40090400070","price":1290.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-wbm-hero-1.png?v=1784417932"},{"product_id":"hi-velocity-wbm-100-chilled-water-base-module","title":"Hi-Velocity WBM-100 Chilled Water Base Module Chilled Water Coil","description":"\u003cp\u003eThe \u003cstrong\u003eWBM-100 Chilled Water Base Module\u003c\/strong\u003e is a chilled-water base cooling coil designed to install directly under the air handler — the same T-mount base configuration as the RBM refrigerant module, but with hydronic connections for chilled water or water-source heat pump systems. Rated for 42–60 MBH cooling at 42°F EWT.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm)\u003c\/li\u003e\n\u003cli\u003eDrain pan with two 3\/4\" M CPVC drain connections (primary + secondary, both P-trap and vented)\u003c\/li\u003e\n\u003cli\u003eTwo T-mounting brackets for base attachment\u003c\/li\u003e\n\u003cli\u003eCompatible with glycol solutions (see manufacturer reduction charts for capacity derating)\u003c\/li\u003e\n\u003cli\u003eApproved for potable water systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity WBM Series (Chilled-Water Base Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e42–60 MBH (12.3–17.6 kW) @ 42°F EWT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eGPM flow rating\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10 GPM (0.63 L\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSupply line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eReturn line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC (primary + secondary)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-P\/HE-B\/HE-100\/101, HV-100\/101, LV-120\/140, LV-Z\/LV-E-1050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e55 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e37\"x19\"x23\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eThe WBM series pairs with chilled-water systems, geothermal loops, water-to-water heat pumps and reverse-cycle chillers — anywhere hydronic cooling is the design of record. For retrofit chilled-water cooling on an already-installed air handler, the WCM add-on module is the return-air-side equivalent.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-wbm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eWBM Chilled Water Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705364761,"sku":"40090400100","price":1512.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-wbm-hero-1.png?v=1784417932"},{"product_id":"hi-velocity-rbm-50-r410a-tx-refrigerant-base-module","title":"Hi-Velocity RBM-50-R410A TX Refrigerant Base Module Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRBM-50-R410A TX Refrigerant Base Module\u003c\/strong\u003e is the R-410A configuration of the RBM-50 Refrigerant Base Module — a heat-pump-ready TX refrigerant cooling coil designed to install directly under a Hi-Velocity SDHV air handler as the module base. Rated for 1.5–2.0 tons of cooling (18–24 MBH TX cooling capacity).\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e22-gauge insulated base cabinet with primary and secondary 3\/4\" M CPVC drain connections\u003c\/li\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm fin thickness)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-410A TX expansion valve with built-in check valve and bypass — heat-pump-ready\u003c\/li\u003e\n\u003cli\u003eFreeze stat and access ports pre-installed\u003c\/li\u003e\n\u003cli\u003eTwo T-mounting brackets for direct connection to air handler\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RBM Series (Refrigerant Base Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal cooling tonnage\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e1.5–2.0 tons (5.3–7.0 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTX cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e18–24 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLatent cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e6.8–8.9 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLiquid line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSuction line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-B\/HE\/HV-50\/51, CU-51, LV-Z\/LV-B-750\/751, LV-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eIncludes\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eTXV, freeze stat, access ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e35 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e37\"x19\"x23\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eThe RBM series installs as the base module under the air handler (T-brackets, integrated drain pan) — the standard configuration when the air handler is being purchased as a heating unit and the cooling stage is added at the same time. For retrofit cooling on an existing installed air handler, use the RCM series (which mounts on the return-air side with L-brackets).\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rbm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRBM Base Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705397529,"sku":"41090300050","price":1591.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rbm-hero-1.png?v=1784417901"},{"product_id":"hi-velocity-rbm-70-r410a-tx-refrigerant-base-module","title":"Hi-Velocity RBM-70-R410A TX Refrigerant Base Module Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRBM-70-R410A TX Refrigerant Base Module\u003c\/strong\u003e is the R-410A configuration of the RBM-70 Refrigerant Base Module — a heat-pump-ready TX refrigerant cooling coil designed to install directly under a Hi-Velocity SDHV air handler as the module base. Rated for 2.5–3.0 tons of cooling (30–36 MBH TX cooling capacity).\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e22-gauge insulated base cabinet with primary and secondary 3\/4\" M CPVC drain connections\u003c\/li\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm fin thickness)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-410A TX expansion valve with built-in check valve and bypass — heat-pump-ready\u003c\/li\u003e\n\u003cli\u003eFreeze stat and access ports pre-installed\u003c\/li\u003e\n\u003cli\u003eTwo T-mounting brackets for direct connection to air handler\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RBM Series (Refrigerant Base Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal cooling tonnage\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e2.5–3.0 tons (8.8–10.6 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTX cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e30–36 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLatent cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e11.7–13.7 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLiquid line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSuction line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-B\/HE\/HV-70\/71, LV-Z\/LV-B-1050\/1051, LV-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eIncludes\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eTXV, freeze stat, access ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e45 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e37\"x19\"x23\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eThe RBM series installs as the base module under the air handler (T-brackets, integrated drain pan) — the standard configuration when the air handler is being purchased as a heating unit and the cooling stage is added at the same time. For retrofit cooling on an existing installed air handler, use the RCM series (which mounts on the return-air side with L-brackets).\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rbm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRBM Base Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705430297,"sku":"41090300070","price":1691.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rbm-hero-1.png?v=1784417901"},{"product_id":"hi-velocity-rbm-100-r410a-tx-refrigerant-base-module","title":"Hi-Velocity RBM-100-R410A TX Refrigerant Base Module Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRBM-100-R410A TX Refrigerant Base Module\u003c\/strong\u003e is the R-410A configuration of the RBM-100 Refrigerant Base Module — a heat-pump-ready TX refrigerant cooling coil designed to install directly under a Hi-Velocity SDHV air handler as the module base. Rated for 3.5–5.0 tons of cooling (42–60 MBH TX cooling capacity).\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e22-gauge insulated base cabinet with primary and secondary 3\/4\" M CPVC drain connections\u003c\/li\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm fin thickness)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-410A TX expansion valve with built-in check valve and bypass — heat-pump-ready\u003c\/li\u003e\n\u003cli\u003eFreeze stat and access ports pre-installed\u003c\/li\u003e\n\u003cli\u003eTwo T-mounting brackets for direct connection to air handler\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RBM Series (Refrigerant Base Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal cooling tonnage\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3.5–5.0 tons (12.3–17.6 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTX cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e42–60 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLatent cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e16.0–22.2 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLiquid line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSuction line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-P\/HE-B\/HE\/HV-100\/101, HE-P-240\/241 (×2 coils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eIncludes\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eTXV, freeze stat, access ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e55 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e37\"x19\"x23\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eThe RBM series installs as the base module under the air handler (T-brackets, integrated drain pan) — the standard configuration when the air handler is being purchased as a heating unit and the cooling stage is added at the same time. For retrofit cooling on an existing installed air handler, use the RCM series (which mounts on the return-air side with L-brackets).\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rbm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRBM Base Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705495833,"sku":"41090300100","price":1948.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rbm-hero-1.png?v=1784417901"},{"product_id":"hi-velocity-rbm-50-a2l-r-454b-r-32-tx-refrigerant-base-module-w-rds-kit","title":"Hi-Velocity RBM-50-A2L (R-454B\/R-32) TX Refrigerant Base Module w\/ RDS Kit Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRBM-50-A2L (R-454B\/R-32) TX Refrigerant Base Module w\/ RDS Kit\u003c\/strong\u003e is the R-454B \/ R-32 (A2L) configuration of the RBM-50 Refrigerant Base Module — a heat-pump-ready TX refrigerant cooling coil designed to install directly under a Hi-Velocity SDHV air handler as the module base. Rated for 1.5–2.0 tons of cooling (18–24 MBH TX cooling capacity). Ships with the Refrigerant Detection System (RDS) Kit — mitigation board plus pre-installed refrigerant sensor — required for A2L (R-454B\/R-32) installations under the 2025 refrigerant regulations.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e22-gauge insulated base cabinet with primary and secondary 3\/4\" M CPVC drain connections\u003c\/li\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm fin thickness)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-454B \/ R-32 (A2L) TX expansion valve with built-in check valve and bypass — heat-pump-ready\u003c\/li\u003e\n\u003cli\u003eFreeze stat and access ports pre-installed\u003c\/li\u003e\n\u003cli\u003eTwo T-mounting brackets for direct connection to air handler\u003c\/li\u003e\n\u003cli\u003eRefrigerant Detection System (RDS Kit) — mitigation board and pre-installed A2L refrigerant sensor\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RBM Series (Refrigerant Base Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-454B \/ R-32 (A2L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal cooling tonnage\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e1.5–2.0 tons (5.3–7.0 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTX cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e18–24 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLatent cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e6.8–8.9 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLiquid line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSuction line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-B\/HE\/HV-50\/51, CU-51, LV-Z\/LV-B-750\/751, LV-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eIncludes\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRDS Kit (mitigation board + refrigerant sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e35 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e37\"x19\"x23\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eThe RBM series installs as the base module under the air handler (T-brackets, integrated drain pan) — the standard configuration when the air handler is being purchased as a heating unit and the cooling stage is added at the same time. For retrofit cooling on an existing installed air handler, use the RCM series (which mounts on the return-air side with L-brackets).\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rbm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRBM Base Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705594137,"sku":"41090304050","price":2332.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rbm-hero-1.png?v=1784417901"},{"product_id":"hi-velocity-rbm-70-a2l-r-454b-r-32-tx-refrigerant-base-module-w-rds-kit","title":"Hi-Velocity RBM-70-A2L (R-454B\/R-32) TX Refrigerant Base Module w\/ RDS Kit Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRBM-70-A2L (R-454B\/R-32) TX Refrigerant Base Module w\/ RDS Kit\u003c\/strong\u003e is the R-454B \/ R-32 (A2L) configuration of the RBM-70 Refrigerant Base Module — a heat-pump-ready TX refrigerant cooling coil designed to install directly under a Hi-Velocity SDHV air handler as the module base. Rated for 2.5–3.0 tons of cooling (30–36 MBH TX cooling capacity). Ships with the Refrigerant Detection System (RDS) Kit — mitigation board plus pre-installed refrigerant sensor — required for A2L (R-454B\/R-32) installations under the 2025 refrigerant regulations.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e22-gauge insulated base cabinet with primary and secondary 3\/4\" M CPVC drain connections\u003c\/li\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm fin thickness)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-454B \/ R-32 (A2L) TX expansion valve with built-in check valve and bypass — heat-pump-ready\u003c\/li\u003e\n\u003cli\u003eFreeze stat and access ports pre-installed\u003c\/li\u003e\n\u003cli\u003eTwo T-mounting brackets for direct connection to air handler\u003c\/li\u003e\n\u003cli\u003eRefrigerant Detection System (RDS Kit) — mitigation board and pre-installed A2L refrigerant sensor\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RBM Series (Refrigerant Base Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-454B \/ R-32 (A2L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal cooling tonnage\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e2.5–3.0 tons (8.8–10.6 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTX cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e30–36 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLatent cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e11.7–13.7 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLiquid line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSuction line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-B\/HE\/HV-70\/71, LV-Z\/LV-B-1050\/1051, LV-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eIncludes\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRDS Kit (mitigation board + refrigerant sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e45 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e37\"x19\"x23\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eThe RBM series installs as the base module under the air handler (T-brackets, integrated drain pan) — the standard configuration when the air handler is being purchased as a heating unit and the cooling stage is added at the same time. For retrofit cooling on an existing installed air handler, use the RCM series (which mounts on the return-air side with L-brackets).\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rbm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRBM Base Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705659673,"sku":"41090304070","price":2459.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rbm-hero-1.png?v=1784417901"},{"product_id":"hi-velocity-rbm-100-a2l-r-454b-r-32-tx-refrigerant-base-module-w-rds-kit","title":"Hi-Velocity RBM-100-A2L (R-454B\/R-32) TX Refrigerant Base Module w\/ RDS Kit Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRBM-100-A2L (R-454B\/R-32) TX Refrigerant Base Module w\/ RDS Kit\u003c\/strong\u003e is the R-454B \/ R-32 (A2L) configuration of the RBM-100 Refrigerant Base Module — a heat-pump-ready TX refrigerant cooling coil designed to install directly under a Hi-Velocity SDHV air handler as the module base. Rated for 3.5–5.0 tons of cooling (42–60 MBH TX cooling capacity). Ships with the Refrigerant Detection System (RDS) Kit — mitigation board plus pre-installed refrigerant sensor — required for A2L (R-454B\/R-32) installations under the 2025 refrigerant regulations.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e22-gauge insulated base cabinet with primary and secondary 3\/4\" M CPVC drain connections\u003c\/li\u003e\n\u003cli\u003eCopper tubing with aluminum fins (0.006 in \/ 0.152 mm fin thickness)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-454B \/ R-32 (A2L) TX expansion valve with built-in check valve and bypass — heat-pump-ready\u003c\/li\u003e\n\u003cli\u003eFreeze stat and access ports pre-installed\u003c\/li\u003e\n\u003cli\u003eTwo T-mounting brackets for direct connection to air handler\u003c\/li\u003e\n\u003cli\u003eRefrigerant Detection System (RDS Kit) — mitigation board and pre-installed A2L refrigerant sensor\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RBM Series (Refrigerant Base Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-454B \/ R-32 (A2L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal cooling tonnage\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3.5–5.0 tons (12.3–17.6 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTX cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e42–60 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLatent cooling capacity (MBH)\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e16.0–22.2 MBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLiquid line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eSuction line\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3\/4\" M CPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eFin material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAluminum (0.006 in \/ 0.152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eTubing material\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCompatible air handlers\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE-Z\/HE-P\/HE-B\/HE\/HV-100\/101, HE-P-240\/241 (×2 coils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eIncludes\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRDS Kit (mitigation board + refrigerant sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e55 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e37\"x19\"x23\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eThe RBM series installs as the base module under the air handler (T-brackets, integrated drain pan) — the standard configuration when the air handler is being purchased as a heating unit and the cooling stage is added at the same time. For retrofit cooling on an existing installed air handler, use the RCM series (which mounts on the return-air side with L-brackets).\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rbm-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRBM Base Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705757977,"sku":"41090304100","price":2773.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rbm-hero-1.png?v=1784417901"},{"product_id":"hi-velocity-rcm-i-50-cooling-module","title":"Hi-Velocity RCM-I-50 Cooling Module Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRCM-I-50 Cooling Module\u003c\/strong\u003e is the RCM-I-50 Refrigerant Cooling Module sized to pair with the HVS-24 (2-ton) inverter-drive heat pump. Heat-pump-ready — the built-in expansion valve includes a check valve, so no field-added TXV is required at the indoor coil.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins\u003c\/li\u003e\n\u003cli\u003e16 Ga galvanized end-sheets and drain pan\u003c\/li\u003e\n\u003cli\u003eTwo 3\/4\" drain-pan connections (primary + secondary)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-410A TX expansion valve with heat-pump-ready check valve\u003c\/li\u003e\n\u003cli\u003eFreeze-stat included\u003c\/li\u003e\n\u003cli\u003emounts on the air handler as an add-on cooling coil (retrofit-friendly, uses L-mounting brackets)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RCM-I Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRCM-I-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003ePaired heat pump\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHVS-24 (2-ton)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e27 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e18\"x11\"x19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eFor use with HVS-24  2-Ton Heat Pump   Fits HE-Z\/HE-B\/HE\/HV-50\/51, CU-51,  LV-Z\/LV-B-750, LV-50 (1.5 - 2 Ton)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eUse with the paired HVS variable-speed heat pump for zoned residential heat-pump installs. The internal check valve means one coil handles both cooling and heat-pump reversing without a second field-installed valve.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-i-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRCM-I Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705823513,"sku":"10090203050","price":1038.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-i-hero-1.png?v=1784417899"},{"product_id":"hi-velocity-rcm-i-70-cooling-module","title":"Hi-Velocity RCM-I-70 Cooling Module Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRCM-I-70 Cooling Module\u003c\/strong\u003e is the RCM-I-70 Refrigerant Cooling Module sized to pair with the HVS-36 (3-ton) inverter-drive heat pump. Heat-pump-ready — the built-in expansion valve includes a check valve, so no field-added TXV is required at the indoor coil.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins\u003c\/li\u003e\n\u003cli\u003e16 Ga galvanized end-sheets and drain pan\u003c\/li\u003e\n\u003cli\u003eTwo 3\/4\" drain-pan connections (primary + secondary)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-410A TX expansion valve with heat-pump-ready check valve\u003c\/li\u003e\n\u003cli\u003eFreeze-stat included\u003c\/li\u003e\n\u003cli\u003emounts on the air handler as an add-on cooling coil (retrofit-friendly, uses L-mounting brackets)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RCM-I Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRCM-I-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003ePaired heat pump\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHVS-36 (3-ton)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e34 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e23\"x19\"x11\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eFor use with HVS-36  3-Ton Heat Pump   (Can also be used with HVS-24) Fits HE-Z\/HE-B\/HE\/HV-70\/71,  LV-Z\/LV-B\/LV-E-1050, LV-70 (2.5 - 3 Ton)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eUse with the paired HVS variable-speed heat pump for zoned residential heat-pump installs. The internal check valve means one coil handles both cooling and heat-pump reversing without a second field-installed valve.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-i-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRCM-I Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705889049,"sku":"10090203070","price":1348.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-i-hero-1.png?v=1784417899"},{"product_id":"hi-velocity-rcm-i-100-cooling-module","title":"Hi-Velocity RCM-I-100 Cooling Module Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRCM-I-100 Cooling Module\u003c\/strong\u003e is the RCM-I-100 Refrigerant Cooling Module sized to pair with the HVS-60 (5-ton) inverter-drive heat pump. Heat-pump-ready — the built-in expansion valve includes a check valve, so no field-added TXV is required at the indoor coil.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins\u003c\/li\u003e\n\u003cli\u003e16 Ga galvanized end-sheets and drain pan\u003c\/li\u003e\n\u003cli\u003eTwo 3\/4\" drain-pan connections (primary + secondary)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-410A TX expansion valve with heat-pump-ready check valve\u003c\/li\u003e\n\u003cli\u003eFreeze-stat included\u003c\/li\u003e\n\u003cli\u003emounts on the air handler as an add-on cooling coil (retrofit-friendly, uses L-mounting brackets)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RCM-I Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRCM-I-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003ePaired heat pump\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHVS-60 (5-ton)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e45 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e30\"x11\"x20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eFor use with HVS-60  5-Ton Heat Pump  (Can also be used with HVS-24, HVS-36) Fits HE-Z\/HE-P\/HE-B\/HE\/HV-100\/101 (3.5 - 5 Ton)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eUse with the paired HVS variable-speed heat pump for zoned residential heat-pump installs. The internal check valve means one coil handles both cooling and heat-pump reversing without a second field-installed valve.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-i-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRCM-I Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819705921817,"sku":"10090203100","price":1443.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rcm-i-hero-1.png?v=1784417899"},{"product_id":"hi-velocity-rbm-i-50-cooling-module","title":"Hi-Velocity RBM-I-50 Cooling Module Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRBM-I-50 Cooling Module\u003c\/strong\u003e is the RBM-I-50 Refrigerant Base Module sized to pair with the HVS-24 (2-ton) inverter-drive heat pump. Heat-pump-ready — the built-in expansion valve includes a check valve, so no field-added TXV is required at the indoor coil.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins\u003c\/li\u003e\n\u003cli\u003e16 Ga galvanized end-sheets and drain pan\u003c\/li\u003e\n\u003cli\u003eTwo 3\/4\" drain-pan connections (primary + secondary)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-410A TX expansion valve with heat-pump-ready check valve\u003c\/li\u003e\n\u003cli\u003eFreeze-stat included\u003c\/li\u003e\n\u003cli\u003einstalls directly under the HE-Z, HE-P, LV-Z or LV-B air handler as the primary evaporator base\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RBM-I Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRBM-I-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003ePaired heat pump\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHVS-24 (2-ton)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e35 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e37\"x19\"x23\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eFor use with HVS-24   2-Ton Heat Pump   Fits HE-Z\/HE-B\/HE\/HV-50\/51, CU-51,  LV-Z\/LV-B-750, LV-50 (1.5 - 2 Ton)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eUse with the paired HVS variable-speed heat pump for zoned residential heat-pump installs. The internal check valve means one coil handles both cooling and heat-pump reversing without a second field-installed valve.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rbm-i-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRBM-I Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819706052889,"sku":"41090303050","price":1266.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rbm-i-hero-1.png?v=1784417902"},{"product_id":"hi-velocity-rbm-i-70-cooling-module","title":"Hi-Velocity RBM-I-70 Cooling Module Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRBM-I-70 Cooling Module\u003c\/strong\u003e is the RBM-I-70 Refrigerant Base Module sized to pair with the HVS-36 (3-ton) inverter-drive heat pump. Heat-pump-ready — the built-in expansion valve includes a check valve, so no field-added TXV is required at the indoor coil.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins\u003c\/li\u003e\n\u003cli\u003e16 Ga galvanized end-sheets and drain pan\u003c\/li\u003e\n\u003cli\u003eTwo 3\/4\" drain-pan connections (primary + secondary)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-410A TX expansion valve with heat-pump-ready check valve\u003c\/li\u003e\n\u003cli\u003eFreeze-stat included\u003c\/li\u003e\n\u003cli\u003einstalls directly under the HE-Z, HE-P, LV-Z or LV-B air handler as the primary evaporator base\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RBM-I Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRBM-I-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003ePaired heat pump\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHVS-36 (3-ton)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e45 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e37\"x19\"x23\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eFor use with HVS-36   3-Ton Heat Pump   (Can also be used with HVS-24) Fits HE-Z\/HE-B\/HE\/HV-70\/71,  LV-Z\/LV-B\/LV-E-1050, LV-70 (2.5 - 3 Ton)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eUse with the paired HVS variable-speed heat pump for zoned residential heat-pump installs. The internal check valve means one coil handles both cooling and heat-pump reversing without a second field-installed valve.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rbm-i-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRBM-I Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819706085657,"sku":"41090303070","price":1479.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rbm-i-hero-1.png?v=1784417902"},{"product_id":"hi-velocity-rbm-i-100-cooling-module","title":"Hi-Velocity RBM-I-100 Cooling Module Refrigerant Coil","description":"\u003cp\u003eThe \u003cstrong\u003eRBM-I-100 Cooling Module\u003c\/strong\u003e is the RBM-I-100 Refrigerant Base Module sized to pair with the HVS-60 (5-ton) inverter-drive heat pump. Heat-pump-ready — the built-in expansion valve includes a check valve, so no field-added TXV is required at the indoor coil.\u003c\/p\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCopper tubing with aluminum fins\u003c\/li\u003e\n\u003cli\u003e16 Ga galvanized end-sheets and drain pan\u003c\/li\u003e\n\u003cli\u003eTwo 3\/4\" drain-pan connections (primary + secondary)\u003c\/li\u003e\n\u003cli\u003eFactory-installed R-410A TX expansion valve with heat-pump-ready check valve\u003c\/li\u003e\n\u003cli\u003eFreeze-stat included\u003c\/li\u003e\n\u003cli\u003einstalls directly under the HE-Z, HE-P, LV-Z or LV-B air handler as the primary evaporator base\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eCoil family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity RBM-I Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRBM-I-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003ePaired heat pump\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHVS-60 (5-ton)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e55 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e37\"x19\"x23\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eFor use with HVS-60   5-Ton Heat Pump  (Can also be used with HVS-24, HVS-36) Fits HE-Z\/HE-P\/HE-B\/HE\/HV-100\/101 (3.5 - 5 Ton)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eUse with the paired HVS variable-speed heat pump for zoned residential heat-pump installs. The internal check valve means one coil handles both cooling and heat-pump reversing without a second field-installed valve.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rbm-i-manual-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRBM-I Cooling Coil Installation Manual\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819706118425,"sku":"41090303100","price":1688.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-rbm-i-hero-1.png?v=1784417902"},{"product_id":"hi-velocity-2-rough-in-kit","title":"Hi-Velocity 2\" Rough-In Kit","description":"\u003cp\u003eThe \u003cstrong\u003e2\" Rough-In Kit\u003c\/strong\u003e is a Hi-Velocity rough-in kit for 2\" Ø branch-duct assemblies. Rough-in Boot, Rough-in Cap (2\")\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eProduct family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity Flexible Duct Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eComponent type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRough-In Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eOutlet size\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e2\" Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRough-in Boot, Rough-in Cap (2\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eComponent-level accessory for the Hi-Velocity flexible-duct system — used during branch assembly, rough-in, or vent-plate finishing. Refer to the Flexible Duct brochure for complete branch-assembly diagrams.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flx-brochure-flexible-duct.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFlexible Duct Brochure\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819706151193,"sku":"10020100100","price":31.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flex-rough-in-kit-1.png?v=1784417878"},{"product_id":"hi-velocity-2-branch-take-off","title":"Hi-Velocity 2\" Branch Take-Off Duct Fitting","description":"\u003cp\u003eThe \u003cstrong\u003e2\" Branch Take-Off\u003c\/strong\u003e is a Hi-Velocity branch take-off for 2\" Ø branch-duct assemblies. Branch Take-Off c\/w Gasket (2\")\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eProduct family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity Flexible Duct Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eComponent type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eBranch Take-Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eOutlet size\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e2\" Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eBranch Take-Off c\/w Gasket (2\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eComponent-level accessory for the Hi-Velocity flexible-duct system — used during branch assembly, rough-in, or vent-plate finishing. Refer to the Flexible Duct brochure for complete branch-assembly diagrams.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flx-brochure-flexible-duct.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFlexible Duct Brochure\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819706183961,"sku":"10020100106","price":17.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flex-branch-take-off-1.png?v=1784417882"},{"product_id":"hi-velocity-2-afd-kit","title":"Hi-Velocity 2\" AFD Kit","description":"\u003cp\u003eThe \u003cstrong\u003e2\" AFD Kit\u003c\/strong\u003e is a Hi-Velocity afd kit for 2\" Ø branch-duct assemblies. Rough-in Boot \u0026amp; Cap, Wh. Plast. Vent Plate, Br. Take-Off (2\")\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eProduct family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity Flexible Duct Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eComponent type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAFD Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eOutlet size\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e2\" Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRough-in Boot \u0026amp; Cap, Wh. Plast. Vent Plate, Br. Take-Off (2\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eComponent-level accessory for the Hi-Velocity flexible-duct system — used during branch assembly, rough-in, or vent-plate finishing. Refer to the Flexible Duct brochure for complete branch-assembly diagrams.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flx-brochure-flexible-duct.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFlexible Duct Brochure\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819706216729,"sku":"10020110002","price":79.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flex-afd-kit-complete-1.png?v=1784417883"},{"product_id":"hi-velocity-2-ufd-kit","title":"Hi-Velocity 2\" UFD Kit","description":"\u003cp\u003eThe \u003cstrong\u003e2\" UFD Kit\u003c\/strong\u003e is a Hi-Velocity ufd kit for 2\" Ø branch-duct assemblies. 3 Branch Connector Tubes, 6 Branch Couplers, 6 Cable Ties (2\")\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eProduct family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity Flexible Duct Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eComponent type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eUFD Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eOutlet size\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e2\" Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e3 Branch Connector Tubes, 6 Branch Couplers, 6 Cable Ties (2\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eComponent-level accessory for the Hi-Velocity flexible-duct system — used during branch assembly, rough-in, or vent-plate finishing. Refer to the Flexible Duct brochure for complete branch-assembly diagrams.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flx-brochure-flexible-duct.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFlexible Duct Brochure\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819706249497,"sku":"10020110004","price":48.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flex-assembly-full-1.png?v=1784417877"},{"product_id":"hi-velocity-2-rough-in-cap","title":"Hi-Velocity 2\" Rough-In Cap","description":"\u003cp\u003eThe \u003cstrong\u003e2\" Rough-In Cap\u003c\/strong\u003e is a Hi-Velocity rough-in cap for 2\" Ø branch-duct assemblies. Rough-In Cap (2\")\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eProduct family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity Flexible Duct Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eComponent type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRough-In Cap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eOutlet size\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e2\" Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRough-In Cap (2\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eComponent-level accessory for the Hi-Velocity flexible-duct system — used during branch assembly, rough-in, or vent-plate finishing. Refer to the Flexible Duct brochure for complete branch-assembly diagrams.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flx-brochure-flexible-duct.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFlexible Duct Brochure\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819706282265,"sku":"10020110302","price":7.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flex-rough-in-cap-1.png?v=1784417880"},{"product_id":"hi-velocity-2-rough-in-cap-extended","title":"Hi-Velocity 2\" Rough-In Cap (Extended)","description":"\u003cp\u003eThe \u003cstrong\u003e2\" Rough-In Cap (Extended)\u003c\/strong\u003e is a Hi-Velocity rough-in cap for 2\" Ø branch-duct assemblies. Rough-In Cap (2\" Extended, Designed for Gypcrete Floors) (2\")\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eProduct family\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHi-Velocity Flexible Duct Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eComponent type\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRough-In Cap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eOutlet size\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e2\" Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eRough-In Cap (2\" Extended, Designed for Gypcrete Floors) (2\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eComponent-level accessory for the Hi-Velocity flexible-duct system — used during branch assembly, rough-in, or vent-plate finishing. Refer to the Flexible Duct brochure for complete branch-assembly diagrams.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flx-brochure-flexible-duct.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFlexible Duct Brochure\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819706544409,"sku":"10020110303","price":9.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flex-rough-in-cap-extended-1.png?v=1784417883"},{"product_id":"hi-velocity-2-x-10-afd-r4-2-flex-4","title":"Hi-Velocity 2\" X 10\" AFD R4.2 Flex (4)","description":"\u003cp\u003eThe \u003cstrong\u003e2\" X 10\" AFD R4.2 Flex (4)\u003c\/strong\u003e is a 10' length of Hi-Velocity 2\" Ø Assembled Flex Duct (AFD) insulated to R-4.2. Ships in the carton quantity noted in the part name.\u003c\/p\u003e\u003ch4\u003eContents\u003c\/h4\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAFD (Assembled) contents:\u003c\/strong\u003e 10' or 15' of flexible duct as specified, two Branch Couplers attached, one Branch Take-Off with Gasket, one Rough-In Boot, one Rough-In Cap, and one Plastic Vent Plate\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDiameter\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e2\" Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLength\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation R-value\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-4.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAssembled Flex Duct (AFD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAssembled 2\" Flex Duct R4.2 - Carton of 4 (1 skid = 25 cartons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eUL Listed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAir Duct, Class 1 (UL 181 \/ CAN\/ULC-S110M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax rated velocity\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e5,000 ft\/min (25.4 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax positive pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10 in. W.C. (2.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax negative pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e0.5 in. W.C. (0.12 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax flame spread\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax smoke developed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInner core\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eFoil laminate + polyester film, .041\" galvanized steel wire, 3\/4\" pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eGREENGUARD-certified fibreglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eVapor barrier\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eMetalized, fibreglass-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e12 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e15\"x15\"x25\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eBranch runs from the main supply plenum to the vent-plate outlets. R-4.2 for conditioned spaces, R-8.4 for unconditioned attics\/crawl-spaces. Standard run length is 10' or 15' for correct airflow and sound attenuation; runs shorter than 10' should be coiled to maintain the 10' minimum, and runs may be extended up to 25'.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flx-brochure-flexible-duct.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFlexible Duct Brochure\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819706577177,"sku":"20020120010","price":458.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flex-2in-hero-1.png?v=1784417880"},{"product_id":"hi-velocity-2-x-15-afd-r4-2-flex-4","title":"Hi-Velocity 2\" X 15\" AFD R4.2 Flex (4)","description":"\u003cp\u003eThe \u003cstrong\u003e2\" X 15\" AFD R4.2 Flex (4)\u003c\/strong\u003e is a 15' length of Hi-Velocity 2\" Ø Assembled Flex Duct (AFD) insulated to R-4.2. Ships in the carton quantity noted in the part name.\u003c\/p\u003e\u003ch4\u003eContents\u003c\/h4\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAFD (Assembled) contents:\u003c\/strong\u003e 10' or 15' of flexible duct as specified, two Branch Couplers attached, one Branch Take-Off with Gasket, one Rough-In Boot, one Rough-In Cap, and one Plastic Vent Plate\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDiameter\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e2\" Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLength\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e15'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation R-value\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-4.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAssembled Flex Duct (AFD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAssembled 2\" Flex Duct R4.2 - Carton of 4 (1 skid = 18 cartons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eUL Listed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAir Duct, Class 1 (UL 181 \/ CAN\/ULC-S110M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax rated velocity\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e5,000 ft\/min (25.4 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax positive pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10 in. W.C. (2.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax negative pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e0.5 in. W.C. (0.12 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax flame spread\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax smoke developed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInner core\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eFoil laminate + polyester film, .041\" galvanized steel wire, 3\/4\" pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eGREENGUARD-certified fibreglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eVapor barrier\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eMetalized, fibreglass-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e18 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e15\"x15\"x35\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eBranch runs from the main supply plenum to the vent-plate outlets. R-4.2 for conditioned spaces, R-8.4 for unconditioned attics\/crawl-spaces. Standard run length is 10' or 15' for correct airflow and sound attenuation; runs shorter than 10' should be coiled to maintain the 10' minimum, and runs may be extended up to 25'.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flx-brochure-flexible-duct.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFlexible Duct Brochure\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819706642713,"sku":"20020120015","price":520.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flex-2in-hero-1.png?v=1784417880"},{"product_id":"hi-velocity-2-x-25-ufd-r4-2-flex-1","title":"Hi-Velocity 2\" X 25' UFD R4.2 Flex (1)","description":"\u003cp\u003eThe \u003cstrong\u003e2\" X 25' UFD R4.2 Flex (1)\u003c\/strong\u003e is a 25' length of Hi-Velocity 2\" Ø Unassembled Flex Duct (UFD) insulated to R-4.2. Ships in the carton quantity noted in the part name.\u003c\/p\u003e\u003ch4\u003eContents\u003c\/h4\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eUFD (Unassembled) contents:\u003c\/strong\u003e 25' of flexible duct plus a UFD Kit (3 Branch Connector Tubes, 6 Branch Couplers, 6 tie wraps)\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDiameter\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e2\" Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLength\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e25'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation R-value\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-4.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eUnassembled Flex Duct (UFD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eUnassembled 2\" Flex Duct R4.2 - Carton of 1 (1 skid = 36 cartons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eUL Listed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAir Duct, Class 1 (UL 181 \/ CAN\/ULC-S110M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax rated velocity\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e5,000 ft\/min (25.4 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax positive pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10 in. W.C. (2.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax negative pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e0.5 in. W.C. (0.12 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax flame spread\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax smoke developed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInner core\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eFoil laminate + polyester film, .041\" galvanized steel wire, 3\/4\" pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eGREENGUARD-certified fibreglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eVapor barrier\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eMetalized, fibreglass-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e12\"x13\"x27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eBranch runs from the main supply plenum to the vent-plate outlets. R-4.2 for conditioned spaces, R-8.4 for unconditioned attics\/crawl-spaces. Standard run length is 10' or 15' for correct airflow and sound attenuation; runs shorter than 10' should be coiled to maintain the 10' minimum, and runs may be extended up to 25'.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flx-brochure-flexible-duct.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFlexible Duct Brochure\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819706675481,"sku":"20020120025","price":204.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flex-2in-hero-1.png?v=1784417880"},{"product_id":"hi-velocity-2-x-10-afd-r8-4-flex-2","title":"Hi-Velocity 2\" X 10' AFD R8.4 Flex (2)","description":"\u003cp\u003eThe \u003cstrong\u003e2\" X 10' AFD R8.4 Flex (2)\u003c\/strong\u003e is a 10' length of Hi-Velocity 2\" Ø Assembled Flex Duct (AFD) insulated to R-8.4. Ships in the carton quantity noted in the part name.\u003c\/p\u003e\u003ch4\u003eContents\u003c\/h4\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAFD (Assembled) contents:\u003c\/strong\u003e 10' or 15' of flexible duct as specified, two Branch Couplers attached, one Branch Take-Off with Gasket, one Rough-In Boot, one Rough-In Cap, and one Plastic Vent Plate\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDiameter\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e2\" Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLength\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation R-value\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-8.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAssembled Flex Duct (AFD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAssembled 2\" Flex Duct R8.4 - Carton of 2 (1 skid = 25 cartons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eUL Listed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAir Duct, Class 1 (UL 181 \/ CAN\/ULC-S110M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax rated velocity\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e5,000 ft\/min (25.4 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax positive pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10 in. W.C. (2.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax negative pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e0.5 in. W.C. (0.12 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax flame spread\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax smoke developed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInner core\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eFoil laminate + polyester film, .041\" galvanized steel wire, 3\/4\" pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eGREENGUARD-certified fibreglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eVapor barrier\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eMetalized, fibreglass-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e15\"x15\"x25\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eBranch runs from the main supply plenum to the vent-plate outlets. R-4.2 for conditioned spaces, R-8.4 for unconditioned attics\/crawl-spaces. Standard run length is 10' or 15' for correct airflow and sound attenuation; runs shorter than 10' should be coiled to maintain the 10' minimum, and runs may be extended up to 25'.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flx-brochure-flexible-duct.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFlexible Duct Brochure\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819706708249,"sku":"20022120010","price":285.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flex-2in-hero-1.png?v=1784417880"},{"product_id":"hi-velocity-2-x-15-afd-r8-4-flex-2","title":"Hi-Velocity 2\" X 15' AFD R8.4 Flex (2)","description":"\u003cp\u003eThe \u003cstrong\u003e2\" X 15' AFD R8.4 Flex (2)\u003c\/strong\u003e is a 15' length of Hi-Velocity 2\" Ø Assembled Flex Duct (AFD) insulated to R-8.4. Ships in the carton quantity noted in the part name.\u003c\/p\u003e\u003ch4\u003eContents\u003c\/h4\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAFD (Assembled) contents:\u003c\/strong\u003e 10' or 15' of flexible duct as specified, two Branch Couplers attached, one Branch Take-Off with Gasket, one Rough-In Boot, one Rough-In Cap, and one Plastic Vent Plate\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDiameter\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e2\" Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLength\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e15'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation R-value\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-8.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAssembled Flex Duct (AFD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAssembled 2\" Flex Duct R8.4 - Carton of 2 (1 skid = 18 cartons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eUL Listed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAir Duct, Class 1 (UL 181 \/ CAN\/ULC-S110M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax rated velocity\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e5,000 ft\/min (25.4 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax positive pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10 in. W.C. (2.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax negative pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e0.5 in. W.C. (0.12 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax flame spread\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax smoke developed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInner core\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eFoil laminate + polyester film, .041\" galvanized steel wire, 3\/4\" pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eGREENGUARD-certified fibreglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eVapor barrier\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eMetalized, fibreglass-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e15 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e15\"x15\"x35\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eBranch runs from the main supply plenum to the vent-plate outlets. R-4.2 for conditioned spaces, R-8.4 for unconditioned attics\/crawl-spaces. Standard run length is 10' or 15' for correct airflow and sound attenuation; runs shorter than 10' should be coiled to maintain the 10' minimum, and runs may be extended up to 25'.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flx-brochure-flexible-duct.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFlexible Duct Brochure\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819706872089,"sku":"20022120015","price":326.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flex-2in-hero-1.png?v=1784417880"},{"product_id":"hi-velocity-2-x-25-ufd-r8-4-flex-1","title":"Hi-Velocity 2\" X 25' UFD R8.4 Flex (1)","description":"\u003cp\u003eThe \u003cstrong\u003e2\" X 25' UFD R8.4 Flex (1)\u003c\/strong\u003e is a 25' length of Hi-Velocity 2\" Ø Unassembled Flex Duct (UFD) insulated to R-8.4. Ships in the carton quantity noted in the part name.\u003c\/p\u003e\u003ch4\u003eContents\u003c\/h4\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eUFD (Unassembled) contents:\u003c\/strong\u003e 25' of flexible duct plus a UFD Kit (3 Branch Connector Tubes, 6 Branch Couplers, 6 tie wraps)\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDiameter\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e2\" Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLength\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e25'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation R-value\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-8.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eUnassembled Flex Duct (UFD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eUnassembled 2\" Flex Duct R8.4 - Carton of 1 (1 skid = 25 cartons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eUL Listed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAir Duct, Class 1 (UL 181 \/ CAN\/ULC-S110M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax rated velocity\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e5,000 ft\/min (25.4 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax positive pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10 in. W.C. (2.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax negative pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e0.5 in. W.C. (0.12 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax flame spread\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax smoke developed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInner core\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eFoil laminate + polyester film, .041\" galvanized steel wire, 3\/4\" pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eGREENGUARD-certified fibreglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eVapor barrier\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eMetalized, fibreglass-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e12 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e15\"x15\"x35\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eBranch runs from the main supply plenum to the vent-plate outlets. R-4.2 for conditioned spaces, R-8.4 for unconditioned attics\/crawl-spaces. Standard run length is 10' or 15' for correct airflow and sound attenuation; runs shorter than 10' should be coiled to maintain the 10' minimum, and runs may be extended up to 25'.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flx-brochure-flexible-duct.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFlexible Duct Brochure\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819706904857,"sku":"20022120025","price":241.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flex-2in-hero-1.png?v=1784417880"},{"product_id":"hi-velocity-he-x-10-afd-r4-2-flex-2","title":"Hi-Velocity HE X 10' AFD R4.2 Flex (2)","description":"\u003cp\u003eThe \u003cstrong\u003eHE X 10' AFD R4.2 Flex (2)\u003c\/strong\u003e is a 10' length of Hi-Velocity HE (2 ¾\" Ø) Assembled Flex Duct (AFD) insulated to R-4.2. Ships in the carton quantity noted in the part name.\u003c\/p\u003e\u003cp\u003eHE Flex is engineered as a direct alternative for two 2\" flex runs in a Hi-Velocity System — one 10' length of HE duct equals two 10' 2\" flex lengths. No changes are required to air-handler selection or main-plenum duct sizing.\u003c\/p\u003e\u003ch4\u003eContents\u003c\/h4\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAFD (Assembled) contents:\u003c\/strong\u003e 10' or 15' of flexible duct as specified, two Branch Couplers attached, one Branch Take-Off with Gasket, one Rough-In Boot, one Rough-In Cap, and one Plastic Vent Plate\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDiameter\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE (2 ¾\" Ø)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLength\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation R-value\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-4.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAssembled Flex Duct (AFD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAssembled HE Flex Duct R4.2 - Carton of 2 (1 skid = 36 cartons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eUL Listed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAir Duct, Class 1 (UL 181 \/ CAN\/ULC-S110M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax rated velocity\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e5,000 ft\/min (25.4 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax positive pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10 in. W.C. (2.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax negative pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e0.5 in. W.C. (0.12 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax flame spread\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax smoke developed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInner core\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eFoil laminate + polyester film, .041\" galvanized steel wire, 3\/4\" pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eGREENGUARD-certified fibreglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eVapor barrier\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eMetalized, fibreglass-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e12\"x13\"x27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eBranch runs from the main supply plenum to the vent-plate outlets. R-4.2 for conditioned spaces, R-8.4 for unconditioned attics\/crawl-spaces. Standard run length is 10' or 15' for correct airflow and sound attenuation; runs shorter than 10' should be coiled to maintain the 10' minimum, and runs may be extended up to 25'.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flx-brochure-flexible-duct.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFlexible Duct Brochure\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819706937625,"sku":"20062010010","price":345.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flex-he-hero-1.png?v=1784417881"},{"product_id":"hi-velocity-he-x-15-afd-r4-2-flex-2","title":"Hi-Velocity HE X 15' AFD R4.2 Flex (2)","description":"\u003cp\u003eThe \u003cstrong\u003eHE X 15' AFD R4.2 Flex (2)\u003c\/strong\u003e is a 15' length of Hi-Velocity HE (2 ¾\" Ø) Assembled Flex Duct (AFD) insulated to R-4.2. Ships in the carton quantity noted in the part name.\u003c\/p\u003e\u003cp\u003eHE Flex is engineered as a direct alternative for two 2\" flex runs in a Hi-Velocity System — one 10' length of HE duct equals two 10' 2\" flex lengths. No changes are required to air-handler selection or main-plenum duct sizing.\u003c\/p\u003e\u003ch4\u003eContents\u003c\/h4\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAFD (Assembled) contents:\u003c\/strong\u003e 10' or 15' of flexible duct as specified, two Branch Couplers attached, one Branch Take-Off with Gasket, one Rough-In Boot, one Rough-In Cap, and one Plastic Vent Plate\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDiameter\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE (2 ¾\" Ø)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLength\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e15'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation R-value\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-4.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAssembled Flex Duct (AFD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAssembled HE Flex Duct R4.2 - Carton of 2 (1 skid = 25 cartons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eUL Listed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAir Duct, Class 1 (UL 181 \/ CAN\/ULC-S110M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax rated velocity\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e5,000 ft\/min (25.4 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax positive pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10 in. W.C. (2.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax negative pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e0.5 in. W.C. (0.12 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax flame spread\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax smoke developed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInner core\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eFoil laminate + polyester film, .041\" galvanized steel wire, 3\/4\" pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eGREENGUARD-certified fibreglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eVapor barrier\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eMetalized, fibreglass-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e12 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e15\"x15\"x26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eBranch runs from the main supply plenum to the vent-plate outlets. R-4.2 for conditioned spaces, R-8.4 for unconditioned attics\/crawl-spaces. Standard run length is 10' or 15' for correct airflow and sound attenuation; runs shorter than 10' should be coiled to maintain the 10' minimum, and runs may be extended up to 25'.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flx-brochure-flexible-duct.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFlexible Duct Brochure\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819706970393,"sku":"20062010015","price":392.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flex-he-hero-1.png?v=1784417881"},{"product_id":"hi-velocity-he-x-25-ufd-r4-2-flex-1","title":"Hi-Velocity HE X 25' UFD R4.2 Flex (1)","description":"\u003cp\u003eThe \u003cstrong\u003eHE X 25' UFD R4.2 Flex (1)\u003c\/strong\u003e is a 25' length of Hi-Velocity HE (2 ¾\" Ø) Unassembled Flex Duct (UFD) insulated to R-4.2. Ships in the carton quantity noted in the part name.\u003c\/p\u003e\u003cp\u003eHE Flex is engineered as a direct alternative for two 2\" flex runs in a Hi-Velocity System — one 10' length of HE duct equals two 10' 2\" flex lengths. No changes are required to air-handler selection or main-plenum duct sizing.\u003c\/p\u003e\u003ch4\u003eContents\u003c\/h4\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eUFD (Unassembled) contents:\u003c\/strong\u003e 25' of flexible duct plus a UFD Kit (3 Branch Connector Tubes, 6 Branch Couplers, 6 tie wraps)\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDiameter\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE (2 ¾\" Ø)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLength\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e25'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation R-value\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-4.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eUnassembled Flex Duct (UFD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eUnassembled HE Flex Duct R4.2 - Carton of 1 (1 skid = 36 cartons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eUL Listed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAir Duct, Class 1 (UL 181 \/ CAN\/ULC-S110M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax rated velocity\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e5,000 ft\/min (25.4 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax positive pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10 in. W.C. (2.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax negative pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e0.5 in. W.C. (0.12 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax flame spread\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax smoke developed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInner core\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eFoil laminate + polyester film, .041\" galvanized steel wire, 3\/4\" pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eGREENGUARD-certified fibreglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eVapor barrier\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eMetalized, fibreglass-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e12\"x13\"x26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eBranch runs from the main supply plenum to the vent-plate outlets. R-4.2 for conditioned spaces, R-8.4 for unconditioned attics\/crawl-spaces. Standard run length is 10' or 15' for correct airflow and sound attenuation; runs shorter than 10' should be coiled to maintain the 10' minimum, and runs may be extended up to 25'.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flx-brochure-flexible-duct.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFlexible Duct Brochure\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819707003161,"sku":"20062010025","price":307.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flex-he-hero-1.png?v=1784417881"},{"product_id":"hi-velocity-he-x-10-afd-r8-4-flex-1","title":"Hi-Velocity HE X 10' AFD R8.4 Flex (1)","description":"\u003cp\u003eThe \u003cstrong\u003eHE X 10' AFD R8.4 Flex (1)\u003c\/strong\u003e is a 10' length of Hi-Velocity HE (2 ¾\" Ø) Assembled Flex Duct (AFD) insulated to R-8.4. Ships in the carton quantity noted in the part name.\u003c\/p\u003e\u003cp\u003eHE Flex is engineered as a direct alternative for two 2\" flex runs in a Hi-Velocity System — one 10' length of HE duct equals two 10' 2\" flex lengths. No changes are required to air-handler selection or main-plenum duct sizing.\u003c\/p\u003e\u003ch4\u003eContents\u003c\/h4\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAFD (Assembled) contents:\u003c\/strong\u003e 10' or 15' of flexible duct as specified, two Branch Couplers attached, one Branch Take-Off with Gasket, one Rough-In Boot, one Rough-In Cap, and one Plastic Vent Plate\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDiameter\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE (2 ¾\" Ø)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLength\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation R-value\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-8.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAssembled Flex Duct (AFD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAssembled HE Flex Duct R8.4 - Carton of 1 (1 skid = 36 cartons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eUL Listed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAir Duct, Class 1 (UL 181 \/ CAN\/ULC-S110M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax rated velocity\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e5,000 ft\/min (25.4 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax positive pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10 in. W.C. (2.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax negative pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e0.5 in. W.C. (0.12 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax flame spread\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax smoke developed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInner core\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eFoil laminate + polyester film, .041\" galvanized steel wire, 3\/4\" pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eGREENGUARD-certified fibreglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eVapor barrier\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eMetalized, fibreglass-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e12\"x13\"x27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eBranch runs from the main supply plenum to the vent-plate outlets. R-4.2 for conditioned spaces, R-8.4 for unconditioned attics\/crawl-spaces. Standard run length is 10' or 15' for correct airflow and sound attenuation; runs shorter than 10' should be coiled to maintain the 10' minimum, and runs may be extended up to 25'.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flx-brochure-flexible-duct.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFlexible Duct Brochure\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819707035929,"sku":"20062030010","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flex-he-hero-1.png?v=1784417881"},{"product_id":"hi-velocity-he-x-15-afd-r8-4-flex-1","title":"Hi-Velocity HE X 15' AFD R8.4 Flex (1)","description":"\u003cp\u003eThe \u003cstrong\u003eHE X 15' AFD R8.4 Flex (1)\u003c\/strong\u003e is a 15' length of Hi-Velocity HE (2 ¾\" Ø) Assembled Flex Duct (AFD) insulated to R-8.4. Ships in the carton quantity noted in the part name.\u003c\/p\u003e\u003cp\u003eHE Flex is engineered as a direct alternative for two 2\" flex runs in a Hi-Velocity System — one 10' length of HE duct equals two 10' 2\" flex lengths. No changes are required to air-handler selection or main-plenum duct sizing.\u003c\/p\u003e\u003ch4\u003eContents\u003c\/h4\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAFD (Assembled) contents:\u003c\/strong\u003e 10' or 15' of flexible duct as specified, two Branch Couplers attached, one Branch Take-Off with Gasket, one Rough-In Boot, one Rough-In Cap, and one Plastic Vent Plate\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ctable style=\"border-collapse:collapse;font-size:0.9em;margin:0.5em 0;border:none;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eDiameter\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eHE (2 ¾\" Ø)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eLength\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e15'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation R-value\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eR-8.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAssembled Flex Duct (AFD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShips as\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAssembled HE Flex Duct R8.4 - Carton of 1  (1 skid = 25 cartons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eUL Listed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eAir Duct, Class 1 (UL 181 \/ CAN\/ULC-S110M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax rated velocity\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e5,000 ft\/min (25.4 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax positive pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e10 in. W.C. (2.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax negative pressure\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e0.5 in. W.C. (0.12 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax flame spread\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eMax smoke developed\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInner core\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eFoil laminate + polyester film, .041\" galvanized steel wire, 3\/4\" pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eInsulation\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eGREENGUARD-certified fibreglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eVapor barrier\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003eMetalized, fibreglass-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e12 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:3px 10px !important;line-height:1.3 !important;text-align:left;font-weight:600;border-top:none;border-bottom:1px solid #e0e0e0;white-space:nowrap;\"\u003eShipping dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:3px 10px !important;line-height:1.3 !important;border-top:none;border-bottom:1px solid #e0e0e0;\"\u003e15\"x15\"x25\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eApplications\u003c\/h4\u003e\u003cp\u003eBranch runs from the main supply plenum to the vent-plate outlets. R-4.2 for conditioned spaces, R-8.4 for unconditioned attics\/crawl-spaces. Standard run length is 10' or 15' for correct airflow and sound attenuation; runs shorter than 10' should be coiled to maintain the 10' minimum, and runs may be extended up to 25'.\u003c\/p\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flx-brochure-flexible-duct.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFlexible Duct Brochure\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-all-spec-sizing.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHi-Velocity Specifications \u0026amp; Sizing Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hi-Velocity","offers":[{"title":"Default Title","offer_id":52819707068697,"sku":"20062030015","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1845\/3717\/files\/hi-velocity-flex-he-hero-1.png?v=1784417881"}],"url":"https:\/\/highvelocityoutlets.com\/es\/collections\/all-hi-velocity-parts-accessories.oembed","provider":"High Velocity Outlets","version":"1.0","type":"link"}